FEATURE

Control Panel

  • Micro-controller based
  • 4 zone control panel
  • On board key pad
  • Two fully programmable codes (master and servant codes)
  • 20000 code combinations
  • One delay zone, one immediate zones, one 24 hour panic zone, one 24 hour fire zone
  • Built in battery backup provision
  • Zone omitting facility 9 led display
  • 5 leds indicate operational status
  • 4 leds indicate individual zone status
  • Entry or exit time 2 to 255 seconds
  • Sounder time 2 to 20 minutes
  • Silent arming
  • Night mode arming
  • Intrusion log
  • Dedicated panic and quick arm keys
  • Power failure indication
  • Blown fuse indication
  • Non-volatile memory
  • 16 key backlit keypad
  • Bell and strobe light outputs
  • Open zone indication
  • Zone status led indicators
  • Automatic rearming after an intrusion
  • Only three incorrect attempts allowed to disarm the system after which the system goes into alarm state Musical audio indication
  • Multiple sounder outputs
  • Elegant white abs body

Built in Speech Dialer

  • Micro-controller based
  • 2 messages
  • Separate intrusion message
  • Separate fire message
  • 15 telephone numbers for intrusion message
  • 15 telephone numbers for fire message
  • 20 second recording time for each message
  • Operates with both tone & pulse
  • Message playback
  • Telephone number check
  • Non-volatile memory
  • Power status led
  • Dialing status led
  • Silent Dialing
  • Can work on EPABX line
  • Self test on reset
  • Line overriding
  • Sound precision switch
  • Musical audio indication
  • In-built tamper switch

TECHNICAL SPECIFICATIONS

Electrical

  • Quiescent current 75 mA typical
  • current with dialing & message play: 160 mA
  • Maximum sounder 1 current output: 1A
  • Maximum sounder 2 current output: 1A
  • Sounder saturation Voltage: Less than l Vat lA
  • Remote keypads: Up to five
  • Non-volatile Memory: Programming and Log
  • Zone response time: Less than 500ms
  • Zone Loop Resistance: Less than 5kohm for NORMALLY CLOSED

Power Supply

  • Mains supply Voltage:220+10%-15%50Hz
  • Total current Output: 800mA at 220V AC (Fuse JA20mm On Main Card)
  • Regulation: Less than 9%
  • Ripple: Less than 200mV RMS
  • Battery Voltage: 12V DC
  • Battery type: SMF Rechargeable
  • Battery Recharge Voltage: 13.8V +/-0-2V DC
  • Fuse: 250ma 20mm AC Mains on PS Card

Environmental

  • Operating Temperature: 0°C to 45°C
  • Storage Temperature: -20°C to 60°C
  • Maximum humidity: 95% non-condensing
  • Environment residential / commercial / light Industrial

Physical

  • Dimensions: 236mm x 226mm x 80mm
  • Max Battery Dimensions: 150mm x 110mm x 64mm

-- Download CINT-04SEC-AS as PDF --