CINT-AX-0-130-2007N

SHORT-RANGE PHOTOELECTRIC DETECTOR

PREMIUM BASIC

AX-TN series is a compact designed photoelectric detector with IP65 high durability rating and accurate optical alignment performance.
These features drastically reduces false alarms caused by severe outdoor environmental changes and it provides a wide range of applications.

IP65 structure with high sealing rubber packing

Rubber packing is used for all conceivable points where water or dust may penetrate, such as wiring holes, wire ports and the outer chassis. Prevention from dust, bugs and water delivers performance with higher reliability against false alarms and breakdowns.

Lightning protection

An improved Electro-Magnetic Interference surge absorber and high surge resistive relay has been installed to protect from lightning surges and maintain stable operation.

Anti-frost hood cover

A hood is installed to prevent frost forming on lower beams. It also makes the maintenance easy because the surface of cover is flat.

Easy angle adjustment

It allows the installer to finely adjust the beam easily.

High grade spherical lens

The high grade spherical lens creates more sharply defined and precise infrared beams compared to ordinary fresnel lenses.

99% beam blocking stability

Enables stable operation with as much as 99% loss of beam energy caused by heavy rain, dust storms, fog or snow.

A.G.C. (Automatic Gain Control) Circuit

A.G.C. circuit continually monitors for gradual changes in the signal’s strength caused by changing weather conditions. It adjusts the sensitivity accordingly to maintain the proper signal level for the current environmental conditions.

Adjustable beam interruption period

The beam interruption time can be adjusted to fit any application. For example, when protecting a wall or fence, a longer interruption time will catch intruders.

SPECIFICATIONS

Model : AX-70TN AX-130TN AX-200TN
Maximum detection range 20m (70ft) 40m (130ft) 60m (200ft)
Maximum arrival distance 200m (700ft) 400m (1300ft) 600m (2000ft)
Detection method Infrared beam interruption detection Infrared beam interruption detection Infrared beam interruption detection
Interruption period Selectable between 50, 100, 250, 500msec (four steps) Selectable between 50, 100, 250, 500msec (four steps) Selectable between 50, 100, 250, 500msec (four steps)
Power supply 10.5 – 28V DC 10.5 – 28V DC 10.5 – 28V DC
Current Consumption 38mA max. 41 mA max. 45mA max.
Alarm period 2sec (±1) Nomina 2sec (±1) Nomina 2sec (±1) Nomina
Alarm output N.C. 28V DC, 0.2A max. N.C. 28V DC, 0.2A max. N.C. 28V DC, 0.2A max.
Tamper switch N.C.; open when cover is removed 28V DC, 0.2A max. 28V DC, 0.2A max.
Operating temperature -35°C – +60°C (-31 °F – +140°F) -35°C – +60°C (-31 °F – +140°F) -35°C – +60°C (-31 °F – +140°F)
Environment humidity 95% max. 95% max. 95% max.
Alignment angle ± 90° Horizontal, ± 5° Vertical ± 90° Horizontal, ± 5° Vertical ± 90° Horizontal, ± 5° Vertical
Location of installation Indoor / Outdoor : Wall / Pole Mounting Indoor / Outdoor : Wall / Pole Mounting Indoor / Outdoor : Wall / Pole Mounting
Weight (Transmitter+ Receiver) 650g (22.9oz) 650g (22.9oz) 650g (22.9oz)

Dimensions

Options